Induction Melting Furnace

Furmace Desktop

1.Hydraulic Dumping Induction Furnace

1.Hydraulic Dumping Induction Furnace

  • Steel shell type furnace
  • Change refractory lining material according to different materials.
  • Steel shell type : for large size melting furnaces with higher structural strength.
2.Hydraulic Dumping Induction Furnace

2.Hydraulic Dumping Induction Furnace

  • Steel shell type furnace
  • Change refractory lining material according to different materials.
  • Steel shell type : for large size melting furnaces with higher structural strength.
3.Power Control Device

3.Power Control Device

  • Power limit stepless control.
  • Power current monitoring and maximum power limit.
4.Power Control Device

4.Power Control Device

  • Power limit stepless control.
  • Power current monitoring and maximum power limit.

Furmace desktop-large size melting furnaces

◆ Direct driving type : suitable for large size melting furnace with higher efficiency.

◆ The furnace is able to melt different metal as the refractory is substituted.

◆ Allows recycled materials to save cost.

◆ High heating speed leads to fast melting, with low alloy oxidation loss.

◆ Electromagnetic wave stirrer blends the molten alloy evenly.

◆ The melt temperature can be controlled through the adjustment of electric power according to the casting melting condition.

◆ Using induction current to heat up and melt the metal directly causes lower operation temperature to the operating environment.

◆ Not having to keep melting remainder in the furnace makes it easy to switch between different materials.

◆ The system can be intermittently or immediately re-operated with cold materials.

◆ No air pollution since no coal or fuel.

Non-contact SCR switch

Non-contact SCR switch

  • DC power supply is controlled by fast response non-contacted SCR, power supply will be cut off in 8.3ms when extraordinary issues are detected.
Redundant breakers and protections

Redundant breakers and protections

  • Fast response circuit breakers on main equipment. ON-OFF power supply without sparks.
  • High speed cutoff at over current or low voltage.
Intelligent power control

Intelligent power control

  • Autocorrecting the input power according to the condition of the material offers a higher overall efficiency.
  • Saving energy costs without effecting productivity.
Multiple monitoring systems for protection

Multiple monitoring systems for protection

  • Power limit stepless control.
  • Power current monitoring and maximum power limit.
  • The power supply will be cut off automatically by SCR switch when the voltage, current or TOT exceeds the safety value.
  • There are 18 signal indicators on the control panel, and each PC board also has its different signal indicator to show the running condition of the equipment, which makes it easier to troubleshoot.
Leak current test of molten metal

Leak current test of molten metal

  • Use galvanometer to detect the leakage of electricity outsize of the refractory lining and show the value on control panel directly.
  • Equipment will automatically be stopped with an indicating signal when leakage exceed the preset value allowed.
TypePower Control Device (Inverter)Melting Material
nput power
(KVA)
Output power
(KW)
Frequency range
(KHz)
Steel 1600℃
(kg/hr)
Iron 1450℃
(kg/hr)
Brass 1175℃
(kg/hr)
Aluminum 730℃
(kg/hr)
CK-7588752~3105110185105
CK-1001181002~3145144260145
CK-1251471252~3190205375190
CK-1501761502~3233245450233
CK-1752051752~3271300525271
CK-2002352002~3310345600310
CK-2252652252~3349405675349
CK-2502942502~3388475750388
CK-3003523001~3465590990465
CK-3504123501~35436801050543
CK-4004704001~36208151200620
CK-4505294501~36989001350698
CK-5005885000.5~177510001500775
CK-6007056000.5~193012001800930
CK-7508827500.5~11163150022501163
CK-8009418000.2~0.61280160025601280
CK-90010599000.2~0.61440180028801440
CK-1000117610000.2~0.61600200032001600
CK-1100135311000.2~0.61760220035201760
CK-1200141212000.2~0.61920240038401920
CK-1500176415000.2~0.62400300048002400
CK-1800211818000.2~0.62880360057602880
CK-2000235220000.2~0.63200400064003200

1.Above data is base on the furnace normal melting rate with continuous operation and compact material infilling, except for the first furnace melting.

2.Input power of rectifier 3Ø 50/60Hz ; 380/415/440/460/480/575VAC(depending on machine type).

3.Thermal efficiency definition : melting material weight /output power of power control device (inverter)*hours (kWh).

4.CHENG KAI MECHTRONIC CO., LTD. reserves the right to change the design and specifications, and the supply of main equipment and accessories is subject to the contract signed with the customer.